Axos-Card-MIB DEFINITIONS ::= BEGIN

IMPORTS
    Integer32,
    Counter64,
    IpAddress,
    mib-2
                    FROM SNMPv2-SMI
    DisplayString,
    MacAddress
                    FROM SNMPv2-TC

    axosModules
        FROM CALIX-PRODUCT-MIB;

    axosCardModule MODULE-IDENTITY
        LAST-UPDATED "202010230000Z"
        ORGANIZATION "Calix"
        CONTACT-INFO
            "       Calix Networks, Inc.

	    Postal: 1035 North McDowell Boulevard
	            Petaluma, CA  94954-1173
		    USA

	     Phone: +1 707 766 3000
	       Fax: +1 707 766 3100

	    E-mail: mib-info@calix.com"
        DESCRIPTION
            "Describes card and OLT ODN port table for Calix Axos
             based products"
        REVISION "202010230000Z"
        DESCRIPTION
            "Initial revision"
    ::= { axosModules 4 }

-- Card Table

axosCardTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF AxosCardEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION "Contains Card entries"
    ::= { axosCardModule 1 }

axosCardEntry OBJECT-TYPE
    SYNTAX      AxosCardEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION "List of attributes related to Card"
    INDEX { axosCardShelf, axosCardSlot }
    ::= { axosCardTable 1 }

AxosCardEntry ::= SEQUENCE {
    axosCardShelf                  Integer32,
    axosCardSlot                   Integer32,
	axosCardAdminStatus            INTEGER,
	axosCardProvType               INTEGER,
	axosCardActualType             INTEGER,
	axosCardSoftwareVersion        OCTET STRING,
	axosCardSerialNumber           DisplayString,
	axosCardCurrentPowerLevel      INTEGER,
	axosCardCleiCode               OCTET STRING,
	axosCardPartNumber             OCTET STRING,
	axosCardStartMacRange          OCTET STRING,
	axosCardEndMacRange            OCTET STRING,
    }

axosCardShelf OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION "Shelf number"
    ::= { axosCardEntry 1 }

axosCardSlot OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION "Slot number"
    ::= { axosCardEntry 2 }

axosCardAdminStatus OBJECT-TYPE
	SYNTAX      INTEGER {
                    unknown(0),
                    enabled(1),
                    alarmsuppress(2),
                    disabled(3)
                }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Administrative status"
    ::= { axosCardEntry 3 }

axosCardProvType OBJECT-TYPE
	SYNTAX      INTEGER {
                    unknown(0),
                    clx3001(1),
                    ng1601(2),
                    gp1601(3),
                    gp1611(4),
                    vdsl2r2(5),
                    ngpon2x4(6),
                    gpon8r2(7),
                    ge12(8),
                    ge24r2(9),
                    epon(10),
                    gpon(11),
                    eponmacsec(12),
                    e32ngpon(13),
                    asm3001(14),
                    gp1612(15),
                    xg801(16),
                    ce201(17),
                    e32xgs(18),
                    frwy(19),
                    xg3201(21),
                    asm5001(22),
                    xg1601(23)
                }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Provisioned card type"
    ::= { axosCardEntry 4 }

axosCardActualType OBJECT-TYPE
	SYNTAX      INTEGER {
                    unknown(0),
                    clx3001(1),
                    ng1601(2),
                    gp1601(3),
                    gp1611(4),
                    vdsl2r2(5),
                    ngpon2x4(6),
                    gpon8r2(7),
                    ge12(8),
                    ge24r2(9),
                    epon(10),
                    gpon(11),
                    eponmacsec(12),
                    e32ngpon(13),
                    asm3001(14),
                    gp1612(15),
                    xg801(16),
                    ce201(17),
                    e32xgs(18),
                    frwy(19),
                    xg3201(21),
                    asm5001(22),
                    xg1601(23)
                }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Actual card type"
    ::= { axosCardEntry 5 }

axosCardSoftwareVersion OBJECT-TYPE
    SYNTAX      OCTET STRING
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Running software version, dotted string notation"
    ::= { axosCardEntry 6 }

axosCardSerialNumber OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Ascii Serial number for card"
    ::= { axosCardEntry 7 }

axosCardCurrentPowerLevel OBJECT-TYPE
    SYNTAX INTEGER {
        notSet(0),
        powerLevelLow(1),
        powerLevel2(2),
        powerLevel3(3),
        powerLevel4(4),
        powerLevelFull(5)
    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Current power level for card"
    ::= { axosCardEntry 8 }

axosCardCleiCode OBJECT-TYPE
    SYNTAX      OCTET STRING
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Ascii CLEI code for card"
    ::= { axosCardEntry 9 }

axosCardPartNumber OBJECT-TYPE
    SYNTAX      OCTET STRING
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Ascii part number"
    ::= { axosCardEntry 10 }

axosCardStartMacRange OBJECT-TYPE
    SYNTAX      OCTET STRING
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Start of MAC range (ascii)"
    ::= { axosCardEntry 11 }

axosCardEndMacRange OBJECT-TYPE
    SYNTAX      OCTET STRING
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "End of MAC range (ascii)"
    ::= { axosCardEntry 12 }

-- Card ODN status

axosOltPonPortTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF AxosOltPonPortEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION "Contains OLT ODN port entries"
    ::= { axosCardModule 2 }

axosOltPonPortEntry OBJECT-TYPE
    SYNTAX      AxosOltPonPortEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION "List of attributes related to OLT ODN port"
    INDEX { axosOltPonPortIfindex }
    ::= { axosOltPonPortTable 1 }

AxosOltPonPortEntry ::= SEQUENCE {
        axosOltPonPortIfindex              Integer32,
        axosOltPonPortName                 OCTET STRING,
        axosOltPonPortStatus               INTEGER,
        axosOltPonPortTemperature          Integer32,
        axosOltPonPortTxBias               Integer32,
        axosOltPonPortTxPower              Integer32,
        axosOltPonPortRxPower              Integer32,
        axosOltPonPortVoltage              Integer32
    }
axosOltPonPortIfindex OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION "A unique value, greater than zero, for each interface. "
    ::= { axosOltPonPortEntry 1 }

axosOltPonPortName OBJECT-TYPE
    SYNTAX      OCTET STRING
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "A textual string containing information about the interface. "
    ::= { axosOltPonPortEntry 2 }

axosOltPonPortStatus OBJECT-TYPE
    SYNTAX      INTEGER {
                    invalid(0),
                    linkUp(1),
                    linkDown(2)
                }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "ODN-I operational status"
    ::= { axosOltPonPortEntry 3 }

axosOltPonPortTemperature OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "ODN-I laser temperature ((value/1000)=degrees Celsius)"
    ::= { axosOltPonPortEntry 4 }

axosOltPonPortTxBias OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "ODN-I laser bias current (muA) "
    ::= { axosOltPonPortEntry 5 }

axosOltPonPortTxPower OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "ODN-I Tx signal level ((value / 10000) = mW) "
    ::= { axosOltPonPortEntry 6 }

axosOltPonPortRxPower OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "ODN-I Rx signal level ((value / 10000) = mW) "
    ::= { axosOltPonPortEntry 7 }

axosOltPonPortVoltage OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "ODN-I voltage in mV "
    ::= { axosOltPonPortEntry 8 }

END