AXOS-ALARM-MIB DEFINITIONS ::= BEGIN

IMPORTS
    NOTIFICATION-TYPE, MODULE-IDENTITY, OBJECT-TYPE, Integer32
        FROM SNMPv2-SMI
    DisplayString
	    FROM SNMPv2-TC
    axosModules
        FROM CALIX-PRODUCT-MIB;

    axosAlarmModule MODULE-IDENTITY
        LAST-UPDATED "201604250000Z"
        ORGANIZATION "Calix"
        CONTACT-INFO
            "       Calix Networks, Inc.

	    Postal: 1035 North McDowell Boulevard
	            Petaluma, CA  94954-1173
		    USA

	     Phone: +1 707 766 3000
	       Fax: +1 707 766 3100

	    E-mail: mib-info@calix.com"
        DESCRIPTION
            "Describes active alarm table for Calix Axos
             based products"
        REVISION "201604250000Z"
        DESCRIPTION
            "Initial revision"
    ::= { axosModules 2 }

    axosAlarm           OBJECT IDENTIFIER ::= {axosAlarmModule 1}
    axosActiveAlarms    OBJECT IDENTIFIER ::= {axosAlarm 1}
    axosEventAttributes OBJECT IDENTIFIER ::= {axosAlarm 3}

--Alarm Table

axosAlarmTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF AxosAlarmEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION "This table holds all the active alarms"
    ::= { axosActiveAlarms 1 }
     
axosAlarmEntry OBJECT-TYPE
    SYNTAX      AxosAlarmEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION "List of attributes regarding alarm table"
    INDEX { axosIndex }
    ::= { axosAlarmTable 1 }

AxosAlarmEntry ::= SEQUENCE {
    axosIndex                 Integer32,
    axosAlarmIndex            Integer32,
    axosAlarmName             DisplayString,
    axosAlarmType             INTEGER,
    axosAlarmCategory         INTEGER,
    axosAlarmInstanceId       DisplayString,
    axosAlarmSeverity         INTEGER,
    axosAlarmServiceAffecting INTEGER,
    axosAlarmAddress          DisplayString,
    axosAlarmText             DisplayString,
    axosAlarmTimeStamp        DisplayString,
    axosAlarmTime             Integer32,
    axosAlarmAdditionalInfo   DisplayString
    }
 
axosAlarmIndex OBJECT-TYPE
    SYNTAX      Integer32 (0..2147483647)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Alarm index from device sequence number"
    ::= { axosAlarmEntry 1 }

axosAlarmName OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Unique name for this alarm. This should match the
                Netconf/Yang notification type."
    ::= { axosAlarmEntry 2 }

axosAlarmType OBJECT-TYPE
    SYNTAX      INTEGER {
                       communication(0),
                       qos(1),
                       processing-error(2),
                       equipment(3),
                       environmental(4),
                       operational-violation(5),
                       integrity-violation(6),
                       informational(7)
                   }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "ITU Event type."
    ::= { axosAlarmEntry 3 }

axosAlarmCategory OBJECT-TYPE
    SYNTAX      INTEGER {
                        general(0),
                        security(1), 
                        dbchange(2),
                        qos(3),
                        environmental(4),
                        tca(5),
                        ntp(6),
                        oam(7),
                        erps(8),
                        g8032(9),
                        rstp(10),
                        port(11),
                        lag(12),
                        lacp(13),
                        arc(14),
                        dhcp(15),
                        ntwkclk(16),
                        pm(17),
                        configuration(18),
                        isis(19),
                        ospf(20),
                        bgp(21),
                        pon(22),
                        bondedgroup(23),
                        cardimgmgmt(24),
                        ontimgmgmt(25),
                        slot(26),
                        subscriber(27),
                        mpls(28),
                        l2vpn(29),
                        aeont(30),
                        bfd(31),
                        vrrp(32),
                        pim(33),
                        connection(34),
                        mfib(35)
                    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Category of the alarm"
    ::= { axosAlarmEntry 4 }

axosAlarmInstanceId OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Non-volatile instance id for this alarm"
    ::= { axosAlarmEntry 5 }

axosAlarmSeverity OBJECT-TYPE
    SYNTAX      INTEGER {
                    critical(0),
                    major(1),
                    minor(2),
                    warning(3),
                    unknown(4),
                    info(5), -- shouldn't be in active alarm list
                    clear(6),-- shouldn't be in active alarm list
                    none(7)  -- shouldn't be in active alarm list
                    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Severity of the alarm"
    ::= { axosAlarmEntry 6 }

axosAlarmServiceAffecting OBJECT-TYPE
    SYNTAX      INTEGER {
                    yes(1),
                    no(2)
                    }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Indicated the nature of the alarm i.e. service
                 affecting or not"
    ::= { axosAlarmEntry 7 }
 
axosAlarmAddress OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "This is the entity that the alarm is raised
                 against. e.g. a port identifier"
    ::= { axosAlarmEntry 8 }

axosAlarmText OBJECT-TYPE
   SYNTAX      DisplayString
   MAX-ACCESS  read-only
   STATUS      current
   DESCRIPTION "Alarm description"
   ::= { axosAlarmEntry 9 } 

axosAlarmTimeStamp OBJECT-TYPE
    SYNTAX      DisplayString(SIZE (1..50))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Timestamp indicating the set/clear time of the
                alarm"
    ::= { axosAlarmEntry 10 }

axosAlarmTime OBJECT-TYPE
   SYNTAX      Integer32
   MAX-ACCESS  read-only
   STATUS      current
   DESCRIPTION "UTC time - this provides a UNIX Epoch fomat of the axosAlarmTimeStamp adjusted for UTC."
   ::= { axosAlarmEntry 11 } 

axosAlarmAdditionalInfo OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Any additional info relevnat to this alarm may
                be provided here"
    ::= { axosAlarmEntry 12 }
 
axosIndex OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Index for this alarm in this table"
    ::= { axosAlarmEntry 13 }


--Alarm Severity Count Group

axosAlarmCount      OBJECT IDENTIFIER ::= {axosActiveAlarms 2}

axosAlarmCountTotal OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "The count of all active alarms"
    ::= { axosAlarmCount 1 }

axosAlarmCountCritical OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "The count of critical alarms"
    ::= { axosAlarmCount 2 }

axosAlarmCountMajor OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "The count of major alarms"
    ::= { axosAlarmCount 3 }

axosAlarmCountMinor OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "The count of minor alarms"
    ::= { axosAlarmCount 4 }

axosAlarmCountWarning OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "The count of warning alarms (reported conditions)"
    ::= { axosAlarmCount 5 }

axosAlarmCountInfo OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "The count of info alarms (unreported conditions)"
    ::= { axosAlarmCount 6 }

-- Event attributes group

axosEventAdditionalInfo1 OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Generic Display string to be used to pass event info"
    ::= { axosEventAttributes 1 }

axosEventAdditionalInfo2 OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Generic Display string to be used to pass event info"
    ::= { axosEventAttributes 2 }

axosEventAdditionalInfo3 OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Generic Display string to be used to pass event info"
    ::= { axosEventAttributes 3 }

axosEventAdditionalInfo4 OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Generic Display string to be used to pass event info"
    ::= { axosEventAttributes 4 }

axosEventAdditionalInfo5 OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Generic Display string to be used to pass event info"
    ::= { axosEventAttributes 5 }

axosEventAdditionalInfo6 OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Generic Display string to be used to pass event info"
    ::= { axosEventAttributes 6 }

axosEventAdditionalInfo7 OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Generic Display string to be used to pass event info"
    ::= { axosEventAttributes 7 }

END